Specialized Design Fixed Prices

UTILITIES

Transmission & Substation Structures

Pedestal Supports for Substation Equipment – Includes: Lightning Arrestor (L.A.), Potential Transformer (P.T.), Metering Unit (C.T./V.T.), Coupling Capacitor Voltage Transformer (C.C.V.T.), Transient Recovery Voltage (T.R.V.), and similar pedestal mounted equipment. All voltages from 33kV – 500kV.  Includes calculations.

Price: $750.00 (+ $400.00 for anchorage and foundation design and calculations)

Bus Dead End Structure, Cantilever Type, Single Bridge – Only insulator dead loads and conductor line loads with no line skew (0 degree).  No other equipment on structure.  Conductor span up to 50′-0 maximum.  Structural design in consideration of electrical (physical) design criteria, including phase to phase, and phase to ground clearances, based on National Electrical Code (NEC).  All voltages up to 500kV.  Includes calculations.

Price: $1600.00 (+400.00 for anchorage and foundation design and calculations)

Line Dead End Structure, Cantilever Type, Single Bridge – Only insulator dead loads and line loads with maximum 30 degree conductor line skew. No stand-offs for ground wire. No other equipment on structure.  Structural design based on line conductor span up to 100′-0 maximum. Line conductor take-off spacing based on minimum phase to phase and phase to ground clearances, based on National Electrical Code (NEC). All voltages up to 66kV.  Includes calculations.

Price: $1800.00 (+400.00 for anchorage and foundation design and calculations)

Line Dead End Structure, Cantilever Type, Single Bridge, w/ Stand-offs for Ground Wire – Only insulator dead loads and line loads with maximum 30 degree conductor line skew and ground wires. No other equipment on structure. Structural design based on line conductor span up to 100′-0 maximum. Line conductor take-off spacing based on minimum phase to phase and phase to ground clearances, based on National Electrical Code (NEC). All voltages up to 115kV to 500kV. Includes calculations.

Price: $1900.00 (+400.00 for anchorage and foundation design and calculations)

Line Dead End Structure, A-Frame Type, Single Bridge – Only insulator dead loads and line loads with maximum 30 degree conductor line skew. No stand-offs for ground wire. No other equipment on structure. Structural design based on line conductor span up to 100′-0 maximum. Line conductor take-off spacing based on minimum phase to phase and phase to ground clearances, based on National Electrical Code (NEC). All voltages up to 66kV. Includes calculations.

Price: $1900.00 (+400.00 for anchorage and foundation design and calculations)

Line Dead End Structure, A-Frame Type, Single Bridge, w/ Stand-offs for Ground Wire – Only insulator dead loads and line loads with maximum 30 degree conductor line skew and ground wires. No other equipment on structure. Structural design based on line conductor span up to 100′-0 maximum. Line conductor take-off spacing based on minimum phase to phase and phase to ground clearances, based on National Electrical Code (NEC). All voltages up to 115kV to 500kV. Includes calculations.

Price: $2000.00 (+400.00 for foundation and anchorage design and calculations)

Transmission & Substation Foundations

Circuit Breaker, Regulator and Similar Electrical Equipment Foundations – Standard pad foundation for electrical equipment. No maintenance pad or operator interface cabinet (O.I.C.).  Includes anchorage, soil bearing, and concrete steel reinforcement calculations. All voltages 4kV to 220kV.

Price: $700.00 (+100.00 for maintenance pad)

Transformer and Similar Skid Mounted Electrical Equipment Foundations – Standard pad foundation for electrical equipment. No maintenance pad or operator interface cabinet (O.I.C.). Includes anchorage, soil bearing, and concrete steel reinforcement calculations. All voltages up to 500kV.

Price: $750.00 (+100.00 for maintenance pad)

Some restrictions apply. Please contact us for details.

ZLS Consulting Inc. (c) 2016. All Rights Reserved.